CAN/CSA C22.2 NO. 60601-2-11-01 (R2009) PDF

CAN/CSA C22.2 NO. 60601-2-11-01 (R2009) PDF

Name:
CAN/CSA C22.2 NO. 60601-2-11-01 (R2009) PDF

Published Date:
06/01/2005

Status:
Active

Description:

Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Gamma Beam Therapy Equipment (Adopted CEI/IEC 60601-2-11:1997, second edition, 1997-08)

Publisher:
Canadian Standards Association / National Standard of Canada

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$69.3
Need Help?

1.1 Scope

Addition:

aa) This Particular Standard specifies requirements for the safety of GAMMA BEAM THERAPY EQUIPMENT intended for RADIOTHERAPY in human medical practice and includes EQUIPMENT in which the selection and DISPLAY of operating parameters can be controlled by a PROGRAMMABLE ELECTRONIC SYSTEM (PES).

bb) This Particular Standard applies to EQUIPMENT which is intended to deliver a GAMMA RADIATION BEAM(S) at NORMAL TREATMENT DISTANCES greater than 5 cm using a SEALED RADIOACTIVE SOURCE(S). For EQUIPMENT operating at shorter distances, special precautions may be necessary.

cc) This Particular Standard applies to EQUIPMENT intended to be:

-used under the authority of appropriately licensed or QUALIFIED PERSONS, by OPERATORS having the skills required for a particular medical application and acting in accordance with the INSTRUCTIONS FOR USE, -maintained at predetermined intervals, -subject to regular checks by the USER, -used for particular specified clinical purposes e.g. STATIONARY RADIOTHERAPY or MOVING BEAM THERAPY.

dd) This Particular Standard is applicable to the manufacture and some installaton aspects of GAMMA BEAM THERAPY EQUIPMENT by the inclusion of TYPE TESTS and SITE TESTS respectively.

ee) This Particular Standard specifies the requirements for EQUIPMENT. It does not specify the requirements for the RADIATION SOURCES.

1.2 Object

Addition:

aa) This Particular Standard establishes requirements to ensure the RADIATION safety and enhance the eletrical and mechanical safety of GAMMA BEAM THERAPY EQUIPMENT used in human medical practice and specifies tests for demonstrating compliance with those requirements.

bb) In EQUIPMENT of the type covered by this Standard, ABSORBED DOSE* is controlled by the time of IRRADIATION. Tolerances for other methods of controlling the ABSORBED DOSE are not included in this standard.


File Size : 1 file , 5.2 MB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 106
Product Code(s) : 2415262, 2415262
Published : 06/01/2005

History

CAN/CSA C22.2 NO. 60601-2-11-01 (R2009)
Published Date: 06/01/2005
Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Gamma Beam Therapy Equipment (Adopted CEI/IEC 60601-2-11:1997, second edition, 1997-08)
$69.3

Related products

CAN/CSA Z15883-5-09 (R2019)
Published Date: 03/01/2009
Washer-disinfectors - Part 5: Test soils and methods for demonstrating cleaning efficacy (Adopted ISO/TS 15883-5:2005, first edition, 2005-11-15)
$67.8

Best-Selling Products

CAN/CSA-ISO/IEC ISP 10608-1-99 (R2003)
Published Date: 02/22/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 1: General Overview and Subnetwork- Independent Requirements (Adopted ISO/IEC 10608-1:1992, first edition)
$21.9
CAN/CSA-ISO/IEC ISP 10608-12-99 (2003)
Published Date: 02/18/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 12: MAC Sublayer and Physical Layer Dependent Requirements for a CSMA/CD LAN Subnetwork (Adopted ISO/IEC ISP 10608-12:1996)
$15.9
CAN/CSA-ISO/IEC ISP 10608-13-01
Published Date: 03/12/2001
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless-Mode Network Service - Part 13: MAC Sublayer and Physical Layer Dependent Requirements for a Token Ring LAN Subnetwork (Adopted ISO/IEC ISP 10608-13:1994, first edition, 1994-0
$15.9
CAN/CSA-ISO/IEC ISP 10608-14-99 (R2003)
Published Date: 02/19/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 14: MAC, PHY and PMD Sublayer Dependent and Station Management Requirements Over an FDDI LAN Subnetwork (Adopted ISO/IEC ISP 10608-14:1995)
$27
CAN/CSA-ISO/IEC ISP 10608-2-99 (R2003)
Published Date: 02/19/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 2: TA51 Profile Including Subnetwork Dependent Requirements for CSMA/CD Local Area Networks (LANs) (Adopted ISO/IEC ISP 10608-2:1992)
$15.9
CAN/CSA-ISO/IEC ISP 10608-4-99 (R2003)
Published Date: 02/18/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 4: Definition of Profile TA53, Operation Over a Token Ring LAN Subnetwork (Adopted ISO/IEC ISP 10608-4:1994, first edition)
$14.1